15.4.2.8 STOP REPLICA Statement

STOP REPLICA [thread_types] [channel_option]

thread_types:
    [thread_type [, thread_type] ... ]

thread_type: IO_THREAD | SQL_THREAD

channel_option:
    FOR CHANNEL channel

Stops the replication threads. From MySQL 8.0.22, use STOP REPLICA in place of STOP SLAVE, which is now deprecated. In releases before MySQL 8.0.22, use STOP SLAVE.

STOP REPLICA requires the REPLICATION_SLAVE_ADMIN privilege (or the deprecated SUPER privilege). Recommended best practice is to execute STOP REPLICA on the replica before stopping the replica server (see Section 7.1.19, “The Server Shutdown Process”, for more information).

Like START REPLICA, this statement may be used with the IO_THREAD and SQL_THREAD options to name the replication thread or threads to be stopped. Note that the Group Replication applier channel (group_replication_applier) has no replication I/O (receiver) thread, only a replication SQL (applier) thread. Using the SQL_THREAD option therefore stops this channel completely.

STOP REPLICA causes an implicit commit of an ongoing transaction. See Section 15.3.3, “Statements That Cause an Implicit Commit”.

gtid_next must be set to AUTOMATIC before issuing this statement.

You can control how long STOP REPLICA waits before timing out by setting the system variable rpl_stop_replica_timeout (from MySQL 8.0.26) or rpl_stop_slave_timeout (before MySQL 8.0.26). This can be used to avoid deadlocks between STOP REPLICA and other SQL statements using different client connections to the replica. When the timeout value is reached, the issuing client returns an error message and stops waiting, but the STOP REPLICA instruction remains in effect. Once the replication threads are no longer busy, the STOP REPLICA statement is executed and the replica stops.

Some CHANGE REPLICATION SOURCE TO | CHANGE MASTER TO statements are allowed while the replica is running, depending on the states of the replication threads. However, using STOP REPLICA prior to executing a CHANGE REPLICATION SOURCE TO | CHANGE MASTER TO statement in such cases is still supported. See Section 15.4.2.3, “CHANGE REPLICATION SOURCE TO Statement”, Section 15.4.2.1, “CHANGE MASTER TO Statement”, and Section 19.4.8, “Switching Sources During Failover”, for more information.

The optional FOR CHANNEL channel clause enables you to name which replication channel the statement applies to. Providing a FOR CHANNEL channel clause applies the STOP REPLICA statement to a specific replication channel. If no channel is named and no extra channels exist, the statement applies to the default channel. If a STOP REPLICA statement does not name a channel when using multiple channels, this statement stops the specified threads for all channels. See Section 19.2.2, “Replication Channels” for more information.

The replication channels for Group Replication (group_replication_applier and group_replication_recovery) are managed automatically by the server instance. STOP REPLICA cannot be used at all with the group_replication_recovery channel, and should only be used with the group_replication_applier channel when Group Replication is not running. The group_replication_applier channel only has an applier thread and has no receiver thread, so it can be stopped if required by using the SQL_THREAD option without the IO_THREAD option.

When the replica is multithreaded (replica_parallel_workers or slave_parallel_workers is a nonzero value), any gaps in the sequence of transactions executed from the relay log are closed as part of stopping the worker threads. If the replica is stopped unexpectedly (for example due to an error in a worker thread, or another thread issuing KILL) while a STOP REPLICA statement is executing, the sequence of executed transactions from the relay log may become inconsistent. See Section 19.5.1.34, “Replication and Transaction Inconsistencies”, for more information.

When the source is using the row-based binary logging format, you should execute STOP REPLICA or STOP REPLICA SQL_THREAD on the replica prior to shutting down the replica server if you are replicating any tables that use a nontransactional storage engine. If the current replication event group has modified one or more nontransactional tables, STOP REPLICA waits for up to 60 seconds for the event group to complete, unless you issue a KILL QUERY or KILL CONNECTION statement for the replication SQL thread. If the event group remains incomplete after the timeout, an error message is logged.

When the source is using the statement-based binary logging format, changing the source while it has open temporary tables is potentially unsafe. This is one of the reasons why statement-based replication of temporary tables is not recommended. You can find out whether there are any temporary tables on the replica by checking the value of Replica_open_temp_tables or Slave_open_temp_tables. When using statement-based replication, this value should be 0 before executing CHANGE REPLICATION SOURCE TO | CHANGE MASTER TO. If there are any temporary tables open on the replica, issuing a CHANGE REPLICATION SOURCE TO | CHANGE MASTER TO statement after issuing a STOP REPLICA causes an ER_WARN_OPEN_TEMP_TABLES_MUST_BE_ZERO warning.