Documentation Home
MySQL 8.0 Reference Manual
Related Documentation Download this Manual
PDF (US Ltr) - 43.2Mb
PDF (A4) - 43.3Mb
Man Pages (TGZ) - 296.0Kb
Man Pages (Zip) - 401.3Kb
Info (Gzip) - 4.3Mb
Info (Zip) - 4.3Mb
Excerpts from this Manual

29.4.4 Pre-Filtering by Instrument

The setup_instruments table lists the available instruments:

mysql> SELECT NAME, ENABLED, TIMED
       FROM performance_schema.setup_instruments;
+---------------------------------------------------+---------+-------+
| NAME                                              | ENABLED | TIMED |
+---------------------------------------------------+---------+-------+
...
| stage/sql/end                                     | NO      | NO    |
| stage/sql/executing                               | NO      | NO    |
| stage/sql/init                                    | NO      | NO    |
| stage/sql/insert                                  | NO      | NO    |
...
| statement/sql/load                                | YES     | YES   |
| statement/sql/grant                               | YES     | YES   |
| statement/sql/check                               | YES     | YES   |
| statement/sql/flush                               | YES     | YES   |
...
| wait/synch/mutex/sql/LOCK_global_read_lock        | YES     | YES   |
| wait/synch/mutex/sql/LOCK_global_system_variables | YES     | YES   |
| wait/synch/mutex/sql/LOCK_lock_db                 | YES     | YES   |
| wait/synch/mutex/sql/LOCK_manager                 | YES     | YES   |
...
| wait/synch/rwlock/sql/LOCK_grant                  | YES     | YES   |
| wait/synch/rwlock/sql/LOGGER::LOCK_logger         | YES     | YES   |
| wait/synch/rwlock/sql/LOCK_sys_init_connect       | YES     | YES   |
| wait/synch/rwlock/sql/LOCK_sys_init_slave         | YES     | YES   |
...
| wait/io/file/sql/binlog                           | YES     | YES   |
| wait/io/file/sql/binlog_index                     | YES     | YES   |
| wait/io/file/sql/casetest                         | YES     | YES   |
| wait/io/file/sql/dbopt                            | YES     | YES   |
...

To control whether an instrument is enabled, set its ENABLED column to YES or NO. To configure whether to collect timing information for an enabled instrument, set its TIMED value to YES or NO. Setting the TIMED column affects Performance Schema table contents as described in Section 29.4.1, “Performance Schema Event Timing”.

Modifications to most setup_instruments rows affect monitoring immediately. For some instruments, modifications are effective only at server startup; changing them at runtime has no effect. This affects primarily mutexes, conditions, and rwlocks in the server, although there may be other instruments for which this is true.

The setup_instruments table provides the most basic form of control over event production. To further refine event production based on the type of object or thread being monitored, other tables may be used as described in Section 29.4.3, “Event Pre-Filtering”.

The following examples demonstrate possible operations on the setup_instruments table. These changes, like other pre-filtering operations, affect all users. Some of these queries use the LIKE operator and a pattern match instrument names. For additional information about specifying patterns to select instruments, see Section 29.4.9, “Naming Instruments or Consumers for Filtering Operations”.

  • Disable all instruments:

    UPDATE performance_schema.setup_instruments
    SET ENABLED = 'NO';

    Now no events are collected.

  • Disable all file instruments, adding them to the current set of disabled instruments:

    UPDATE performance_schema.setup_instruments
    SET ENABLED = 'NO'
    WHERE NAME LIKE 'wait/io/file/%';
  • Disable only file instruments, enable all other instruments:

    UPDATE performance_schema.setup_instruments
    SET ENABLED = IF(NAME LIKE 'wait/io/file/%', 'NO', 'YES');
  • Enable all but those instruments in the mysys library:

    UPDATE performance_schema.setup_instruments
    SET ENABLED = CASE WHEN NAME LIKE '%/mysys/%' THEN 'YES' ELSE 'NO' END;
  • Disable a specific instrument:

    UPDATE performance_schema.setup_instruments
    SET ENABLED = 'NO'
    WHERE NAME = 'wait/synch/mutex/mysys/TMPDIR_mutex';
  • To toggle the state of an instrument, flip its ENABLED value:

    UPDATE performance_schema.setup_instruments
    SET ENABLED = IF(ENABLED = 'YES', 'NO', 'YES')
    WHERE NAME = 'wait/synch/mutex/mysys/TMPDIR_mutex';
  • Disable timing for all events:

    UPDATE performance_schema.setup_instruments
    SET TIMED = 'NO';